Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
IEEE Trans Med Imaging ; 43(1): 162-174, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37432808

RESUMEN

Four-dimensional magnetic resonance imaging (4D-MRI) is an emerging technique for tumor motion management in image-guided radiation therapy (IGRT). However, current 4D-MRI suffers from low spatial resolution and strong motion artifacts owing to the long acquisition time and patients' respiratory variations. If not managed properly, these limitations can adversely affect treatment planning and delivery in IGRT. In this study, we developed a novel deep learning framework called the coarse-super-resolution-fine network (CoSF-Net) to achieve simultaneous motion estimation and super-resolution within a unified model. We designed CoSF-Net by fully excavating the inherent properties of 4D-MRI, with consideration of limited and imperfectly matched training datasets. We conducted extensive experiments on multiple real patient datasets to assess the feasibility and robustness of the developed network. Compared with existing networks and three state-of-the-art conventional algorithms, CoSF-Net not only accurately estimated the deformable vector fields between the respiratory phases of 4D-MRI but also simultaneously improved the spatial resolution of 4D-MRI, enhancing anatomical features and producing 4D-MR images with high spatiotemporal resolution.


Asunto(s)
Radioterapia Guiada por Imagen , Humanos , Movimiento (Física) , Radioterapia Guiada por Imagen/métodos , Redes Neurales de la Computación , Imagen por Resonancia Magnética/métodos
2.
Radiother Oncol ; 189: 109948, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37832790

RESUMEN

BACKGROUND AND PURPOSE: Motion estimation from severely downsampled 4D-MRI is essential for real-time imaging and tumor tracking. This simulation study developed a novel deep learning model for simultaneous MR image reconstruction and motion estimation, named the Downsampling-Invariant Deformable Registration (D2R) model. MATERIALS AND METHODS: Forty-three patients undergoing radiotherapy for liver tumors were recruited for model training and internal validation. Five prospective patients from another center were recruited for external validation. Patients received 4D-MRI scans and 3D MRI scans. The 4D-MRI was retrospectively down-sampled to simulate real-time acquisition. Motion estimation was performed using the proposed D2R model. The accuracy and robustness of the proposed D2R model and baseline methods, including Demons, Elastix, the parametric total variation (pTV) algorithm, and VoxelMorph, were compared. High-quality (HQ) 4D-MR images were also constructed using the D2R model for real-time imaging feasibility verification. The image quality and motion accuracy of the constructed HQ 4D-MRI were evaluated. RESULTS: The D2R model showed significantly superior and robust registration performance than all the baseline methods at downsampling factors up to 500. HQ T1-weighted and T2-weighted 4D-MR images were also successfully constructed with significantly improved image quality, sub-voxel level motion error, and real-time efficiency. External validation demonstrated the robustness and generalizability of the technique. CONCLUSION: In this study, we developed a novel D2R model for deformation estimation of downsampled 4D-MR images. HQ 4D-MR images were successfully constructed using the D2R model. This model may expand the clinical implementation of 4D-MRI for real-time motion management during liver cancer treatment.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Neoplasias Hepáticas , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Movimiento (Física) , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia
3.
Int J Radiat Oncol Biol Phys ; 117(2): 493-504, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37116591

RESUMEN

PURPOSE: The objective of this study was to develop a respiratory-correlated (RC) 4-dimensional (4D) imaging technique based on magnetic resonance fingerprinting (MRF) (RC-4DMRF) for liver tumor motion management in radiation therapy. METHODS AND MATERIALS: Thirteen patients with liver cancer were prospectively enrolled in this study. k-space MRF signals of the liver were acquired during free-breathing using the fast acquisition with steady-state precession sequence on a 3T scanner. The signals were binned into 8 respiratory phases based on respiratory surrogates, and interphase displacement vector fields were estimated using a phase-specific low-rank optimization method. Hereafter, the tissue property maps, including T1 and T2 relaxation times, and proton density, were reconstructed using a pyramid motion-compensated method that alternatively optimized interphase displacement vector fields and subspace images. To evaluate the efficacy of RC-4DMRF, amplitude motion differences and Pearson correlation coefficients were determined to assess measurement agreement in tumor motion between RC-4DMRF and cine magnetic resonance imaging (MRI); mean absolute percentage errors of the RC-4DMRF-derived tissue maps were calculated to reveal tissue quantification accuracy using digital human phantom; and tumor-to-liver contrast-to-noise ratio of RC-4DMRF images was compared with that of planning CT and contrast-enhanced MRI (CE-MRI) images. A paired Student t test was used for statistical significance analysis with a P value threshold of .05. RESULTS: RC-4DMRF achieved excellent agreement in motion measurement with cine MRI, yielding the mean (± standard deviation) Pearson correlation coefficients of 0.95 ± 0.05 and 0.93 ± 0.09 and amplitude motion differences of 1.48 ± 1.06 mm and 0.81 ± 0.64 mm in the superior-inferior and anterior-posterior directions, respectively. Moreover, RC-4DMRF achieved high accuracy in tissue property quantification, with mean absolute percentage errors of 8.8%, 9.6%, and 5.0% for T1, T2, and proton density, respectively. Notably, the tumor contrast-to-noise ratio in RC-4DMRI-derived T1 maps (6.41 ± 3.37) was found to be the highest among all tissue property maps, approximately equal to that of CE-MRI (6.96 ± 1.01, P = .862), and substantially higher than that of planning CT (2.91 ± 1.97, P = .048). CONCLUSIONS: RC-4DMRF demonstrated high accuracy in respiratory motion measurement and tissue properties quantification, potentially facilitating tumor motion management in liver radiation therapy.


Asunto(s)
Neoplasias Hepáticas , Protones , Humanos , Imagen por Resonancia Magnética/métodos , Movimiento (Física) , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Respiración , Espectroscopía de Resonancia Magnética , Fantasmas de Imagen
4.
Quant Imaging Med Surg ; 12(7): 3917-3931, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35782269

RESUMEN

Background: Coronavirus disease 2019 (COVID-19) is a pandemic disease. Fast and accurate diagnosis of COVID-19 from chest radiography may enable more efficient allocation of scarce medical resources and hence improved patient outcomes. Deep learning classification of chest radiographs may be a plausible step towards this. We hypothesize that bone suppression of chest radiographs may improve the performance of deep learning classification of COVID-19 phenomena in chest radiographs. Methods: Two bone suppression methods (Gusarev et al. and Rajaraman et al.) were implemented. The Gusarev and Rajaraman methods were trained on 217 pairs of normal and bone-suppressed chest radiographs from the X-ray Bone Shadow Suppression dataset (https://www.kaggle.com/hmchuong/xray-bone-shadow-supression). Two classifier methods with different network architectures were implemented. Binary classifier models were trained on the public RICORD-1c and RSNA Pneumonia Challenge datasets. An external test dataset was created retrospectively from a set of 320 COVID-19 positive patients from Queen Elizabeth Hospital (Hong Kong, China) and a set of 518 non-COVID-19 patients from Pamela Youde Nethersole Eastern Hospital (Hong Kong, China), and used to evaluate the effect of bone suppression on classifier performance. Classification performance, quantified by sensitivity, specificity, negative predictive value (NPV), accuracy and area under the receiver operating curve (AUC), for non-suppressed radiographs was compared to that for bone suppressed radiographs. Some of the pre-trained models used in this study are published at (https://github.com/danielnflam). Results: Bone suppression of external test data was found to significantly (P<0.05) improve AUC for one classifier architecture [from 0.698 (non-suppressed) to 0.732 (Rajaraman-suppressed)]. For the other classifier architecture, suppression did not significantly (P>0.05) improve or worsen classifier performance. Conclusions: Rajaraman suppression significantly improved classification performance in one classification architecture, and did not significantly worsen classifier performance in the other classifier architecture. This research could be extended to explore the impact of bone suppression on classification of different lung pathologies, and the effect of other image enhancement techniques on classifier performance.

5.
Med Phys ; 49(5): 3159-3170, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35171511

RESUMEN

BACKGROUND: Most available four-dimensional (4D)-magnetic resonance imaging (MRI) techniques are limited by insufficient image quality and long acquisition times or require specially designed sequences or hardware that are not available in the clinic. These limitations have greatly hindered the clinical implementation of 4D-MRI. PURPOSE: This study aims to develop a fast ultra-quality (UQ) 4D-MRI reconstruction method using a commercially available 4D-MRI sequence and dual-supervised deformation estimation model (DDEM). METHODS: Thirty-nine patients receiving radiotherapy for liver tumors were included. Each patient was scanned using a time-resolved imaging with interleaved stochastic trajectories (TWIST)-lumetric interpolated breath-hold examination (VIBE) MRI sequence to acquire 4D-magnetic resonance (MR) images. They also received 3D T1-/T2-weighted MRI scans as prior images, and UQ 4D-MRI at any instant was considered a deformation of them. A DDEM was developed to obtain a 4D deformable vector field (DVF) from 4D-MRI data, and the prior images were deformed using this 4D-DVF to generate UQ 4D-MR images. The registration accuracies of the DDEM, VoxelMorph (normalized cross-correlation [NCC] supervised), VoxelMorph (end-to-end point error [EPE] supervised), and the parametric total variation (pTV) algorithm were compared. Tumor motion on UQ 4D-MRI was evaluated quantitatively using region of interest (ROI) tracking errors, while image quality was evaluated using the contrast-to-noise ratio (CNR), lung-liver edge sharpness, and perceptual blur metric (PBM). RESULTS: The registration accuracy of the DDEM was significantly better than those of VoxelMorph (NCC supervised), VoxelMorph (EPE supervised), and the pTV algorithm (all, p < 0.001), with an inference time of 69.3 ± 5.9 ms. UQ 4D-MRI yielded ROI tracking errors of 0.79 ± 0.65, 0.50 ± 0.55, and 0.51 ± 0.58 mm in the superior-inferior, anterior-posterior, and mid-lateral directions, respectively. From the original 4D-MRI to UQ 4D-MRI, the CNR increased from 7.25 ± 4.89 to 18.86 ± 15.81; the lung-liver edge full-width-at-half-maximum decreased from 8.22 ± 3.17 to 3.65 ± 1.66 mm in the in-plane direction and from 8.79 ± 2.78 to 5.04 ± 1.67 mm in the cross-plane direction, and the PBM decreased from 0.68 ± 0.07 to 0.38 ± 0.01. CONCLUSION: This novel DDEM method successfully generated UQ 4D-MR images based on a commercial 4D-MRI sequence. It shows great promise for improving liver tumor motion management during radiation therapy.


Asunto(s)
Neoplasias Hepáticas , Imagen por Resonancia Magnética , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Movimiento (Física)
6.
Med Phys ; 48(10): 6421-6436, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34514608

RESUMEN

PURPOSE: Four-dimensional cone-beam computed tomography (4D CBCT) is developed to reconstruct a sequence of phase-resolved images, which could assist in verifying the patient's position and offering information for cancer treatment planning. However, 4D CBCT images suffer from severe streaking artifacts and noise due to the extreme sparse-view CT reconstruction problem for each phase. As a result, it would cause inaccuracy of treatment estimation. The purpose of this paper was to develop a new 4D CBCT reconstruction method to generate a series of high spatiotemporal 4D CBCT images. METHODS: Considering the advantage of (DL) on representing structural features and correlation between neighboring pixels effectively, we construct a novel DL-based method for the 4D CBCT reconstruction. In this study, both a motion-aware dictionary and a spatially structural 2D dictionary are trained for 4D CBCT by excavating the spatiotemporal correlation among ten phase-resolved images and the spatial information in each image, respectively. Specifically, two reconstruction models are produced in this study. The first one is the motion-aware dictionary learning-based 4D CBCT algorithm, called motion-aware DL based 4D CBCT (MaDL). The second one is the MaDL equipped with a prior knowledge constraint, called pMaDL. Qualitative and quantitative evaluations are performed using a 4D extended cardiac torso (XCAT) phantom, simulated patient data, and two sets of patient data sets. Several state-of-the-art 4D CBCT algorithms, such as the McKinnon-Bates (MKB) algorithm, prior image constrained compressed sensing (PICCS), and the high-quality initial image-guided 4D CBCT reconstruction method (HQI-4DCBCT) are applied for comparison to validate the performance of the proposed MaDL and prior constraint MaDL (pMaDL) pmadl reconstruction frameworks. RESULTS: Experimental results validate that the proposed MaDL can output the reconstructions with few streaking artifacts but some structural information such as tumors and blood vessels, may still be missed. Meanwhile, the results of the proposed pMaDL demonstrate an improved spatiotemporal resolution of the reconstructed 4D CBCT images. In these improved 4D CBCT reconstructions, streaking artifacts are suppressed primarily and detailed structures are also restored. Regarding the XCAT phantom, quantitative evaluations indicate that an average of 58.70%, 45.25%, and 40.10% decrease in terms of root-mean-square error (RMSE) and an average of 2.10, 1.37, and 1.37 times in terms of structural similarity index (SSIM) are achieved by the proposed pMaDL method when compared with piccs, PICCS, MaDL(2D), and MaDL(2D), respectively. Moreover the proposed pMaDL achieves a comparable performance with HQI-4DCBCT algorithm in terms of RMSE and SSIM metrics. However, pMaDL has a better ability to suppress streaking artifacts than HQI-4DCBCT. CONCLUSIONS: The proposed algorithm could reconstruct a set of 4D CBCT images with both high spatiotemporal resolution and detailed features preservation. Moreover the proposed pMaDL can effectively suppress the streaking artifacts in the resultant reconstructions, while achieving an overall improved spatiotemporal resolution by incorporating the motion-aware dictionary with a prior constraint into the proposed 4D CBCT iterative framework.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada de Haz Cónico Espiral , Algoritmos , Tomografía Computarizada Cuatridimensional , Humanos , Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen
7.
IEEE Trans Med Imaging ; 40(11): 3054-3064, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34010129

RESUMEN

Four-dimensional cone-beam computed tomography (4D CBCT) has been developed to provide a sequence of phase-resolved reconstructions in image-guided radiation therapy. However, 4D CBCT images are degraded by severe streaking artifacts and noise because the phase-resolved image is an extremely sparse-view CT procedure wherein a few under-sampled projections are used for the reconstruction of each phase. Aiming at improving the overall quality of 4D CBCT images, we proposed two CNN models, named N-Net and CycN-Net, respectively, by fully excavating the inherent property of 4D CBCT. To be specific, the proposed N-Net incorporates the prior image reconstructed from entire projection data based on U-Net to boost the image quality for each phase-resolved image. Based on N-Net, a temporal correlation among the phase-resolved images is also considered by the proposed CycN-Net. Extensive experiments on both XCAT simulation data and real patient 4D CBCT datasets were carried out to verify the feasibility of the proposed CNNs. Both networks can effectively suppress streaking artifacts and noise while restoring the distinct features simultaneously, compared with the existing CNN models and two state-of-the-art iterative algorithms. Moreover, the proposed method is robust in handling complicated tasks of various patient datasets and imaging devices, which implies its excellent generalization ability.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada de Haz Cónico Espiral , Algoritmos , Tomografía Computarizada Cuatridimensional , Humanos , Procesamiento de Imagen Asistido por Computador , Redes Neurales de la Computación , Fantasmas de Imagen
8.
Med Phys ; 47(5): 2099-2115, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32017128

RESUMEN

PURPOSE: Four-dimensional cone-beam computed tomography (4D CBCT) has been developed to provide a sequence of phase-resolved reconstructions in image-guided radiation therapy. However, 4D CBCT images are degraded by severe streaking artifacts because the 4D CBCT reconstruction process is an extreme sparse-view CT procedure wherein only under-sampled projections are used for the reconstruction of each phase. To obtain a set of 4D CBCT images achieving both high spatial and temporal resolution, we propose an algorithm by providing a high-quality initial image at the beginning of the iterative reconstruction process for each phase to guide the final reconstructed result toward its optimal solution. METHODS: The proposed method consists of three steps to generate the initial image. First, a prior image is obtained by an iterative reconstruction method using the measured projections of the entire set of 4D CBCT images. The prior image clearly shows the appearance of structures in static regions, although it contains blurring artifacts in motion regions. Second, the robust principal component analysis (RPCA) model is adopted to extract the motion components corresponding to each phase-resolved image. Third, a set of initial images are produced by the proposed linear estimation model that combines the prior image and the RPCA-decomposed motion components. The final 4D CBCT images are derived from the simultaneous algebraic reconstruction technique (SART) equipped with the initial images. Qualitative and quantitative evaluations were performed by using two extended cardiac-torso (XCAT) phantoms and two sets of patient data. Several state-of-the-art 4D CBCT algorithms were performed for comparison to validate the performance of the proposed method. RESULTS: The image quality of phase-resolved images is greatly improved by the proposed method in both phantom and patient studies. The results show an outstanding spatial resolution, in which streaking artifacts are suppressed to a large extent, while detailed structures such as tumors and blood vessels are well restored. Meanwhile, the proposed method depicts a high temporal resolution with a distinct respiratory motion change at different phases. For simulation phantom, quantitative evaluations of the simulation data indicate that an average of 36.72% decrease at EI phase and 42% decrease at EE phase in terms of root-mean-square error (RMSE) are achieved by our method when comparing with PICCS algorithm in Phantom 1 and Phantom 2. In addition, the proposed method has the lowest entropy and the highest normalized mutual information compared with the existing methods in simulation experiments, such as PRI, RPCA-4DCT, SMART, and PICCS. And for real patient cases, the proposed method also achieves the lowest entropy value compared with the competitive method. CONCLUSIONS: The proposed algorithm can generate an optimal initial image to improve iterative reconstruction performance. The final sequence of phase-resolved volumes guided by the initial image achieves high spatiotemporal resolution by eliminating motion-induced artifacts. This study presents a practical 4D CBCT reconstruction method with leading image quality.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada Cuatridimensional , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Humanos , Análisis de Componente Principal , Control de Calidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...